Finite Element Modeling of Cell Exposed To Harmonic and Transient Electric Fields - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Magnetics Année : 2007

Finite Element Modeling of Cell Exposed To Harmonic and Transient Electric Fields

Résumé

The transmembrane potential (TMP) of a cell exposed to harmonic or transient electric fields is the main parameter for a successful permeabilization of a cell. Obviously, TMP can be computed with a Finite Element Method, but the high contrast between sizes and electromagnetic properties of the cytoplasm, the membrane, and the extra-cellular medium leads sometimes to inaccurate numerical results. Influences of membrane conductivity and frequency on the accuracy are studied. Optimization of transient waveforms is proposed for various shapes of cells.
Fichier principal
Vignette du fichier
full_paper_cefc10418_ieee_modifie.pdf (183.45 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-00136656 , version 1 (19-03-2007)
hal-00136656 , version 2 (10-04-2007)

Identifiants

Citer

Yvan Meny, Noël Burais, François Buret, Laurent Nicolas. Finite Element Modeling of Cell Exposed To Harmonic and Transient Electric Fields. IEEE Transactions on Magnetics, 2007, 43 (4), pp.1773--1776. ⟨10.1109/TMAG.2007.892517⟩. ⟨hal-00136656v1⟩